Lead Forensics
ZIP

No samples were found in your basket.

Outgassing

Outgassing in Harwin plastics

Outgassing is the release of gas that was dissolved, trapped or absorbed in any material. Although this does happen under normal conditions to a small extent, the effect is most notable in vacuum or near-vacuum conditions. For Harwin products, this is a possibility for all plastics used in the manufacture of our products.

Harwin has requested information from our plastic suppliers to confirm outgassing figures for these materials. The information is given in the following table or you can download the PDF version here.

If the product you are interested in is not listed, do please contact [email protected] for investigation.

Plastic material Outgassing data Used in Harwin products
LCP - Zenite 6130L 0.06% TML, 0.00% CVCM (NASA data) Customer Special products.
LCP - Vectra C130 0.03% TML, 0.00% CVCM (NASA data) Customer Special products.
LCP - Vectra E130 0.04% TML, 0.02% CVCM (NASA data) Data applicable for Vectra/Laperos E130i, used on:
M22-654, M22-655, M22-713, M22-714, M402VF, M402VM, M40-600, M40-620, M50-310, M50-312, M50-355, M50-365, M50-430, M50-470, M50-480, M50-490, M50-491, M60-6XX, M701-340542.
PA46 - Stanyl TE250F6 Black Fog = 0.06mg after 16h @100°C (DIN 75201-G gravimetric)

Test data for similar Stanyl 46HF5050: Pellets = 0.75% TML, <0.01% CVCM Moulded part = 1.01% TML, <0.01% CVCM

Selected Datamate L-Tek:
M80-611, M80-613, M80-614, M80-615, M80-616, M80-617, M80-681, M80-690, M80-691, M80-752, M80-753, M80-754, M80-763, M80-770, M80-771, M80-781, M80-782, M80-788, M80-789, M80-790, M80-791, M80-792, M80-793, M80-796, M80-798, M80-806, M80-807, M80-808, M80-809, M80-810, M80-811, M80-812, M80-813, M80-816, M80-817, M80-822, M80-823, M80-824, M80-825, M80-831, M80-832, M80-839, M80-840, M80-841, M80-842, M80-843, M80-844, M80-845, M80-846, M80-850, M80-851, M80-852, M80-853, M80-854, M80-863, M80-881, M80-882, M80-883, M80-884.

All M80-7XX Legacy 3-row series:
M80-700, M80-701, M80-702, M80-703, M80-704, M80-705, M80-706, M80-707, M80-708, M80-709, M80-710, M80-711, M80-714, M80-715, M80-716, M80-717, M80-718, M80-740, M80C107422C, M80C107424C.

Datamate J-Tek Trio-Tek:
M80-454, M80-455, M80-456, M80-457, M80-458, M80-459.

Datamate J-Tek (backshells only, not connector housing): M80-940, M80-941, M80-942, M80-943.

Other products:
D01-992XX46, D01-993XX46, D01-994XX46, M90-60X, M90-70X, S8401, all W2XXX except W2222.

PA4T - ForTii F11 GN61400 Green 0.68% TML, 0.01% CVCM, 0.26 WVR (Water Vapour Recovered) Gecko:
G125-204, G125-224, G125-304, G125-324, G125-FC, G125-FS, G125-FV, G125-MC, G125-MH, G125-MS, G125-MV.

M300:
M300-22X, M300-32X, M300-FV, M300-MV.

PA6T - Arlen CH230N 854ppm total emission after 10 minutes at 320°C Data applicable for Arlen CH230NK, used on: M20-610XX45, M20-611XX45, M22-600, M22-601, M22-603, M50-350, M50-360, M50-390, M50 Pin Header Variants.

Data applicable for Arlen E430N, used on:
M20-785, M20-890, M20-970, M20-971, M20-972, M20-973, M20-974, M20-975, M20-976, M20-977, M20-995, M20-996, M20-997, M20-998, M20-999, M20 Pin Header Variants, M22-201, M22-202, M22-203, M22-204, M22-241, M22-251, M22-252, M22-253, M22-254, M22-258, M22-271, M22-272, M22-273, M22-274, M22 Pin Header Variants, M50-300, M50-315, M50-361, M52-505, M52-515, M52 Pin Header Variants.

Data applicable for Arlen E430N(T5), used on: M20-786, M20-787, M20-789.

Data applicable for Arlen E430NK-T5, used on:
M20-875, M20-876, M20-877, M22-530, M22-532, M22-552, M22-602, M52-500, M52-510.

PA66 - Zytel 101F White 1.14% TML, 0.01% CVCM (NASA data) Plastic Spacers:
R30-161, R30-670, R40-671.
PBT - Valox 420SEO Black 95-97% reflectance (DIN 75201)

0.33% TML, 0.07% CVCM (NASA data)

Selected Datamate L-Tek:
all B5740, all B5741, all B5743, M80-101, M80-103, M80-804, M80-805, M80-814, M80-815, M80-819, M80-820, M80-855, M80-856, M80-858, M80-864, M80-865, M80-866, M80-867, M80-868, M80-869, M80-876, M80-877, M80-878, M80-879, M80-880, M80-887, M80-888, M80-889, M80-891, M80-894, M80-897, M80-898, M80-899.

Other products:
D01-992XX01, D01-993XX01, D01-994XX01, K3600, K3601, K3700, K3701, M22-19X, M7565, M7566, M7567, M7571, M7765, M7766, M7767, M7771, M7965, M7966, M7967, M7971, R30-940.

Data also applicable for Valox 310SESO, used on: M7680 to M7687.

PCT - ThermX CG907 0.67% TML, 0.01% CVCM (NASA data) Data applicable for ThermX CG933, used on:
D01-995, D01-997, D07XX, D08XX, D09XX, D26XX, D27XX, D28XX, D29XX, D39XX, D73064, D8864, D95XXX.
PPS - Fortron 1140L4 Natural VOC <0.95µg/g, Fog <0.95µg/g (to VDA 278 / PB VWL 709)

0.05% TML, 0.00% CVCM (NASA data)

Data applicable for Fortron 1140A6 Black, used on: M20-615, M20-616, S8411, S8421.

Data applicable for Fortron 1131L4 Black, used on:
Selected Datamate: all M80-4 (other than M80-454, M80-455, M80-456, M80-457, M80-458, M80-459), all M80-5, M80-665, M80-666, M80-667, M80-826, M80-827, M80-828, M80-835, M80-836, M80-837, M80-FC, M80-MH, M80-MV.
Datamate Hooded J-Tek (connector mould, not backshells): M80-940, M80-941, M80-942, M80-943.
All M83 connectors (Datamate 3-Row).
Does not include any coax insulation.

PPE+PS - Noryl SE100 Gray 0.09% TML, 0.00% CVCM (NASA data) Data applicable for Noryl SE100X, used on: M20-106, M20-107.

The NASA outgassing data was obtained using test ASTM E 595-77/84/90 "Total Mass Loss (TML) and Collected Volatile Condensable Materials (CVCM) from Outgassing in a Vacuum Environment". Materials having a value of 1% TML or less, and 0.1% CVCM or less, are described by NASA as"Low Outgassing". The data is listed on the dedicated Outgassing page on the NASA website.

Share:

Live Chat Request Samples
Back to top