M80-4000000FC-10-PF5-00-000
10 Pos. Female SIL 10AWG Cable Conn. Kit, 101Lok
4.00mm Pitch High-Reliability Connector - Datamate Power
- Complete kit: housing (with 101Lok slotted head) with 10 x high power contacts supplied loose.
- Rated to 40A nominal, Power solder contact suitable for 10AWG. Gold finish on contact area and termination.
- For complete pin numbering or pin out information, see Component Specification C005XX.
Technical Details
Specification
EU RoHS Status:
Contact Pitch:
4.00mm (0.157")
Contact Gender:
Female/Socket/Jack
Connector Orientation:
Straight
Connection Type:
Cable (Solder)
Cable Conductor Size:
10AWG
Current Rating:
40A max per contact
Operating Temperature:
-55°C to +125°C
Style of Jackscrews:
101Lok
Polarising Features:
End Stackable:
No
Side Stackable:
No
Can be cut to another size:
No
Number of Rows:
1
Number of Special (Power or Coax) Contacts:
10
Materials
Finish / Plating on Termination:
Gold
Finish / Plating on Contact Surface:
Gold
Base Material of Contact:
Beryllium Copper
Housing Material:
PPS
Housing Colour:
Black
Housing Material UL Rating:
UL94V-0
Packaging Style:
Single Pack
Dimensions
Individual Part Weight:
5.733g
Overall Dimensions (L x W x D) in mm:
50.00 x 5.50 x 13.70
Mating Profiles:
Availability

Low availability or made to order: This product is typically manufactured to order. When out of stock, minimum order quantities may apply.
* Please request minimum quantities, lead times and pricing from an authorized distributor.
Questions & Answers Ask a Question
Can I use a Metal Backshell (M80-945 or M80-946) with this connector?
Sorry no, I’m afraid the metal backshells are not compatible with Datamate Mix-Tek connectors fitted with 10AWG High Power contacts. You will need to specify an alternative contact from the standard power contacts (32x or M80-32x), one that uses 12 to 20AWG cable. Do please contact our Experts if you need assistance specifying an alternative.
We see the power contacts are up to 80A peak. What is the duration of the peak current pulse?
You can see further information on the testing carried out on current in the Test Report HT040 – the current rating was established using a continuous current. Pulse current was not used, and may give a different result. We would recommend that if this is an important criteria for you, you should carry out your own testing. If you need further advice or more detail on any aspects of the test report, please contact our Experts.
Downloads
TECHNICAL DOCUMENTS
TEST REPORTS
ENVIRONMENTAL COMPLIANCE
INSTRUCTION SHEETS
OTHER DOWNLOADS
Want to talk to someone?
If you would like to talk to someone about Harwin’s product, technical knowledge or documentation, contact one of our Experts for assistance.